ATTENTION: To reduce the risk of electric
shock, do not remove cover. Refer servicing to
qualified service personnel. Disconnect the mains
supply before connecting or disconnecting the
links to the battery.
Read the Instruction Manual carefully before use.
Verify that the selected charge curve is suitable
for the type of battery You have to re-charge.
Explanation of Graphical Symbols:
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence
of uninsulated "dangerous voltage" within the equipment's enclosure; that may be of sufficient magnitude to constitute
a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating
and maintenance (servicing) instructions in the literature accompanying the equipment.
This product is covered by warranty.
The relative warranty certificate is attached to the Instructions Manual.
If the Manual is not provided with this certificate, please ask your retailer for a copy.
For further references, please write the serial number in the proper space:
Serial No.
Information contained in this Manual relates to ZIVAN S.r.l. property which reserves the right to supply for the exclusive use of customers.
No other use is allowed without a written authorization supplied by ZIVAN S.r.l.
______________________________________________________________________________________________________
|ZIVAN S.r.l. will be not responsible for inaccuracies contained in this manual due to print or translation errors. ZIVAN S.r.l. has the right to
make changes or improvements, also for the user interest, without prejudicing the essential characteristic of operation and safety. ____________
Installation and safety instructions
Battery charger NG5-7-9 plus has been designed to provide safety and reliable. It is necessary to observe the following precautions in order to
avoid damage to persons and to the battery charger:
Read the installation instructions contained in this Manual carefully. For further information put the Manual in a proper place.
Fix the battery charger to a stable surface through the appropriate holes inserted on the fixing flanges. In case of installation on a
vehicle it is advisable to use anti-vibration supports.
Preferably the charger should be installed in the vertical position with the fan facing up. The horizontal installation is allowed. Never
install in the vertical position with the fan facing down.
Ensure all ventilation ports are not obstructed, to avoid the overheating. Do not put the battery charger near heat sources. Make sure
that free space around the battery charger is sufficient to provide adequate ventilation and an easy access to cables sockets.
Protect the battery charger from ingress of water. Do not pour liquids inside the case.
Verify that the available supply voltage corresponds to the voltage that is stated on the battery charger name plate. In case of doubt,
consult a retailer or local Electric Supply Authority.
As protection device in the input of the battery charger You can both use a switch of AC class, but it is warmly recommended to use
one of A class or even better one of B class.
For safety and electromagnetic compatibility, the battery charger has a 3-prong plug as a safety feature, and it will only fit into an
earthed outlet. If you can´t plug it in, chances are you have an older, non-earthed outlet; contact an electrician to have the outlet
replaced. Do not use an adapter to defeat the grounding.
To avoid damaging the power cord, do not put anything on it or place it where it will be walked on. If the cord becomes damaged or
frayed, replace it immediately.
If you are using an extension cord or power strip, make sure that the total of the amperes required by all the equipment on the
extension is less than the extension's rating.
Disconnect the mains supply (turn off the switch) before connecting or disconnecting the links to the battery.
To recharge Lead Acid batteries: WARNING: Explosive Gas - Avoid flames and sparks. The battery must be positioned in a correctly
cooled place.
Do not use to charge batteries installed on board of thermal engine cars. '
Avoid recharging of non-rechargeable batteries.
Verify that the nominal voltage of the battery to be re-charged corresponds to the voltage stated on the battery charger name plate.
Verify that the selected charging curve is suitable for the type of battery to be re-charged, in case of doubt, consult Your retailer. ZIVAN
S.r.l. will not accept any responsibility in case of mistaken choice of the charging curve that may cause irreversible damage to the
battery.
In order to avoid voltage drop, thereby assuring 100% charge at the battery, the output cables must be as short as possible, and the
diameter must be adequate for the output current.
Do not try to service the battery charger yourself. Opening the cover may expose you to shocks or other hazards.
If the battery charger does not work correctly or if it has been damaged, unplugged it immediately from the supply socket and from the
battery socket and contact a retailer.
D01570-02 9
NG5-7-9 CAN Bus Interface English
Vista de página 0
1 2 3 4 5

Resumo do Conteúdo

Página 1 - D01570-02 9

ATTENTION: To reduce the risk of electric shock, do not remove cover. Refer servicing to qualified service personnel. Disconnect the mains suppl

Página 2

Visualization Digital InstrumentDuring the first minute after starting, on the digital instrument it will be displayed the value of the voltage drop o

Página 3 - D01570-02

NG5-7-9 CAN Bus Interface Charging curve selection You can press the MODE button according two modalities: 1. Long pressure (at least 1 second): al

Página 4

Auxiliary contacts NG5-7-9 CAN Bus Interface Connector PinN0 Description C 1-2 Start/Stop Hardware D 1 -BATT. 2 Thermal sensor contact 3 Temperature

Página 5 - Protection and Safety

TECHNICAL FEATURES Ta =25°C unless otherwise specified Mains side NG5-7-9 CAN Bus Interface Description Symbol Test Condition Value and/or Range Uni